02 / TACTILE SENSOR FOR GRIPPERS

Three-Axis Tactile
Sensor for Grippers

Research on a three-axis tactile sensor for integration into robotic grippers.

23 Groups · 69 SectorsCAN FD3-Axis Sensing
Front, rear and side views and assembly CAD of the gripper tactile sensor.
Front, rear and side views and assembly CAD of the gripper tactile sensor.
Hardware fabrication · Three-axis loading · Gripper integrationRESEARCH PROJECT / 02
Groups / sectors
23 / 69
Three electrodes per group
Contact area
25 × 50 mm
Gripper finger contact surface
Multichannel readout
6 CDCs
CAN FD · 100 Hz output
01 / RESEARCH NOTES

Gripper contact demonstration

The two tactile pads mounted on the gripper are pressed in turn to observe force and contact position. The left panel shows the physical contact; the right panel shows each pad’s contact position, force vector and three-axis time traces.

Manual contact test of two tactile pads mounted on a gripper · 29 sec
02 / RESEARCH NOTES

Electrode array and multichannel electronics

The circular electrode is still divided into three sectors, while the number of groups increases from four to 23. Deformation of the conductive silicone and dielectric under contact load changes the capacitance of each sector.

Sensing electrodes and readout circuits are arranged on a four-layer PCB with six capacitance-to-digital converters. Sensing traces are organized into six active-shield regions.

Sensing array
23 groups / 69 sectors
PCB / readout
4 layers / 6 CDCs
Power supply
5 V
Communication / output rate
CAN FD / 100 Hz
Reported normal-force range
0–40 N
Reported shear-force range
±15 N
03 / RESEARCH NOTES

Sensor fabrication and assembly

The conductive contact layer and dielectric were molded, aligned with the electrode groups, and bonded in place. Calibration was performed after assembly because layer thickness, alignment and bonding conditions affect the signals.

04 / RESEARCH NOTES

Three-axis comparison with a reference sensor

Normal and two-axis shear loads were applied repeatedly using an AFT150 force/torque sensor as the reference. Reference signals were acquired through IXXAT Classical CAN and tactile signals through PCAN CAN FD, then aligned in time and coordinates.

The reference-loading procedure follows that of the fingertip sensor, with coefficients fitted for the gripper’s channel layout and assembled state. Compression is plotted as negative Fz in the records below.

Sources and interpretationBased on gripper sensor design and fabrication records, reference-sensor comparisons and the integrated-sensor demonstration video.